Wood fiber panels FiberTherm Install


Wood fiber FiberTherm Install


Wood fiber panels with density of 140 Kg/m³.
Fibertherm Install is a wood fiber panel for internal thermal insulation of walls and roofs. Available with either a smooth surface or a milled surface.

Data sheet Wood fiber panels FiberTherm installDownload Data sheet
Specification Wood fiber panels FiberTherm installDownload Specification
Price list Wood fiber FiberThermDownload Price list

Related articles




DESCRIPTION

The FiberTherm Install wood fiber panel is a thermo-acoustic insulation for the internal lining of roofs and walls. FiberTherm Install panels are available with either smooth or milled surfaces.

The material is also recyclable, with relative NaturePlus certification and made exclusively with wood from controlled forests in compliance with the FSC directives.

• ideal for preparing wooden assembly levels (eg solid wood walls);
• can be fixed as an internal lining;
• no independent frame is required;
• quick, cheap;
• ideal for prefabricating assembly structures;
• the ducts can be easily milled;
• individual millings on request;
• recyclable, ecological, respects the environment;
• tested and authorized building material based on current European standards.

AVAILABLE DIMENSIONS
   insulating panels with smooth surface



Thickness (mm) Dimension (mm) Weight/m²(kg) Panels/Pallet m²/Pallet Weight/Pallet(kg)
50 2600x600 7,00 4468,6 approx.490


AVAILABLE DIMENSIONS
  insulating panels with milled surface


Thickness (mm) Dimension (mm) Weight/m²(kg) Panels/Pallet m²/Pallet Weight/Pallet(kg)
50 1250x2595 5,60 22 71,3 approx.410


General indications:
• stack horizontally and dry;
• pay particular attention to the edges of the panels;
• remove the pallet packaging only when it is on a flat, stable and dry surface.

TECHNICAL CHARACTERISTICS


Density (kg/m³) approx. 140
Reaction to fire according to the EN standard 13501-1 E
Coefficient of thermal conductivity λD W/(m∗K) 0,040
Specific heat c [J/(kg∗K)] 2.100
Resistance to vapor diffusion μ 3
sd value (m) 0,15
Thermal resistance   RD [(m² · K)/W] 1,25
Compression strenght (kPa) ≥100
Traction resistance perpendicular to the faces (kPa) 10
Length correlated with flow resistance [(kPa · s)/m²] ≥100
Short-term water absorption (kg/m²) ≤2,0
Manufacturing controlled according to the legislation EN 13171
Panels identification WF-EN13171-T5-CS(10/Y)100-TR10-MU3
Waste code (EAK) 030105 /170201